Specification
Specifications - Construction
Inner Conductor |
Copper tube |
Φ 13.0 mm |
Dielectric |
Cellular polyethylene |
Φ 32.2 mm |
Outer Conductor |
Corrugated copper tube |
Φ 35.8 mm |
Jacketing |
Black, halogen-free fire-retardant thermoplastic |
Φ 39.0 mm |
Marking |
Trademark, cable type, manufacture week, year, batch number and meter mark |
-- |
Specifications - Electrical Characteristics at +20°C
Characteristic Impedance |
50 ± 1 Ω |
Return Loss |
Typical: 24 dB(1.13) for 100 m cable with NKC connector |
Attenuation |
See table below |
Velocity Factor |
0.88 |
Capacitance |
76.0 pF/m |
Cut-off Frequency |
3700 MHz |
Max Power Rating |
See table below |
Peak RF Voltage Rating |
4.6 kV |
Peak Power Rating |
194.0 kW |
DC resistance |
Inner conductor: 0.64 Ω/km, Outer conductor: 0.55 Ω/km |
Frequency (MHz) |
Attenuation (dB/100m) |
Power Rating (kW) |
|
Frequency (MHz) |
Attenuation (dB/100m) |
Power Rating (kW) |
10 |
0.250 |
41 |
|
950 |
2.79 |
3.6 |
30 |
0.439 |
23 |
|
1000 |
2.87 |
3.5 |
50 |
0.571 |
18 |
|
1200 |
3.18 |
3.1 |
100 |
0.819 |
12 |
|
1400 |
3.48 |
2.8 |
200 |
1.18 |
8.5 |
|
1600 |
3.76 |
2.6 |
300 |
1.47 |
6.8 |
|
1800 |
4.03 |
2.4 |
400 |
1.72 |
5.8 |
|
1900 |
4.16 |
2.4 |
450 |
1.83 |
5.4 |
|
2000 |
4.29 |
2.3 |
500 |
1.94 |
5.1 |
|
2200 |
4.54 |
2.2 |
600 |
2.15 |
4.6 |
|
2400 |
4.79 |
2.0 |
700 |
2.34 |
4.2 |
|
2600 |
5.02 |
1.9 |
800 |
2.53 |
3.9 |
|
2800 |
5.26 |
1.9 |
850 |
2.61 |
3.8 |
|
3000 |
5.48 |
1.8 |
900 |
2.70 |
3.7 |
|
3300 |
5.81 |
1.7 |
* Attenuation values are typical at ambient temperature +20°C. Power rating ambient temperature +40°C, inner conductor +100°C.
Specifications - Mechanical Characteristics
Weight |
0.94 kg/m |
Maximum Pulling Force |
2500 N |
Minimum Bending Radius |
Single Bending: 200mm, Repeated Bending: 350 mm |
Operating Temperature Range |
-40 ~ +70 °C |